Set AquaWiz Controller + external Display
€899.00
Available, delivery time: 1-3 days
Product information "Set AquaWiz Controller + external Display"
SET: AquaWiz KH Controller Gen 5 + AquaWiz Wireless Touchscreen Display
This set combines the 5th-generation AquaWiz KH Controller with the matching AquaWiz Wireless Touchscreen Display – perfectly matched for automatic KH measurement and control and for a permanent display of all key values right at the aquarium.
Set Contents
– 1 × AquaWiz KH Controller, 5th generation
– 1 × AquaWiz Wireless Touchscreen Display
Set component 1: AquaWiz Wireless Touchscreen Display for Gen 3, Gen 4 and Gen 5 KH Controllers
Keep an eye on your aquarium’s alkalinity (KH) and the status of your AquaWiz controller at all times – with the AquaWiz Wireless Touchscreen Display.
This compact, full-colour touchscreen display connects wirelessly to your AquaWiz KH Controller and permanently shows your aquarium’s most important readings and controller information. No more constantly opening the AquaWiz app.
Place the display next to the aquarium, in the equipment area, or mount it on the outside of the aquarium cabinet – for a clear, professional-looking monitoring station.
Ideal for demanding reef aquariums, SPS-dominated tanks, coral farms, retail display aquariums and any system where constant KH monitoring is essential.
Displayed Information
- Current KH value
- Current pH value
- Target KH value
- Dosing status
- Probe health
- Pump status
- Current test status
- AquaWiz controller operating information
Features
- Full-colour touchscreen display
- Wireless connection to the AquaWiz KH Controller
- Clear, easy-to-read display of live aquarium data
- Controller monitoring without the app
- Compact design for desk, cabinet or equipment area
- Multilingual user interface
- USB-C power supply
- Compatible with AquaWiz Gen 3, Gen 4 and Gen 5 KH Controllers
Compatibility
Compatible with:
- AquaWiz Gen 5 KH Controller
- AquaWiz Gen 4 KH Controller
- AquaWiz Gen 3 KH Controller
The 5th-generation AquaWiz KH Controller is already included in this set.
Set component 2: AquaWiz – The 5th-Generation KH Controller!
Smarter, sleeker and with groundbreaking pH analysis!
Say goodbye to cans and bottles of test reagents and the tedious daily routine! This revolutionary invention, the AquaWiz KH Controller™, automatically measures and regulates the KH in your aquarium.
All you need to prepare is a “reference solution”. This can be natural seawater, your existing aquarium water or freshly mixed synthetic seawater with stable alkalinity. The reference solution is recycled and reused during the measuring process.
The reference solution is reused during the measuring process. This measuring method produces no waste water and no acid solution.
The 5th generation is here – smarter, sleeker and with groundbreaking pH analysis!
New Design & Easy Setup
The 5th generation impresses with a modern matte finish for a premium look. Even more importantly, the entire setup is now done directly via your smartphone – intuitive, fast and without a PC or complicated connection steps.
NEW: ΔpH Indicator Analysis – More Insight, Less Maintenance
A real highlight is the newly developed ΔpH analysis function – a smart method of assessing water quality via the difference between the current pH value (pH) and the theoretical maximum value after complete aeration (pH(O)).
The ΔpH = pH – pH(O) metric provides a reliable indicator of the system’s condition – independent of calibration drift or probe ageing. A value above –0.3 indicates a stable and healthy aquarium environment.
Your benefits at a glance:
- Less calibration required:
Monitoring ΔpH automatically shows when calibration makes sense – without relying on potentially distorted absolute pH values. - Optimisation made easy:
ΔpH responds noticeably to environmental factors such as aeration, CO₂ concentration or lighting. Users can test specific measures and monitor the effect in real time. - Early detection of malfunctions: Sudden ΔpH changes often indicate problems with equipment components (e.g. skimmer, aeration) – allowing a quick response.
“Absolute values can be deceiving – but differential values tell the truth.”
With the combination of smart setup, new design and forward-looking ΔpH technology, the 5th generation is our most powerful system yet – for everyone who wants to redefine control, stability and ease of use in marine aquaristics.
Contents + Technical Information:
- Under the cover: DIY-friendly design. Control circuit, pump.
- Buttons: Three buttons, from left to right: [- / L], [+ / R], [Enter / Select].
- pH probe (PH IN): Compatible with all aquarium pH probes.
- Power supply: 12V 1A input.
- KH dosing (inlet/outlet):
- Inlet: Draws in the KH solution.
- Outlet: Delivers the solution into your aquarium to raise the KH.
If the KH falls below the target value, it can be topped up as needed.
- KH-to-pH output (BNC connector): Can be used with Apex, Ekoral or pH monitors to display KH values.
More Information
Further information and application notes on our products can be found at https://www.faunamarin.de/support-downloads/ and on our YouTube channel: Fauna Marin YouTube channel
Operating Instructions - AquaWiz Gen 5
Setup
Horizontal placement of the KH controller:
Place the KH controller horizontally. The AquaWiz does not have to be perfectly level, but should be located as close as possible to the aquarium or sump.
Inserting the pH probe:
- Remove the pH probe from its storage bottle and check for cracks in the glass bulb or electrolyte leaks. The pH glass bulb is extremely fragile.
- Open the top cover of the controller, carefully insert the pH probe into the opening of the left reagent tube and lift the left air stone so that it does not touch the pH glass bulb.
- Make sure the pH glass bulb hangs approx. 0.5 cm above the bottom of the reagent tube to avoid breakage.
- Plug the pH connector into the rear BNC socket.
- Close the top cover and tighten the screws.
- After inserting the pH probe, wait 3 minutes; during A6 the LCD should normally show "LF 100". If "LF 0" or "Error" is displayed, the probe is defective; replace the probe.
- The pH probe lifetime is shown hourly on the website; do not judge the condition of a new probe based on this information.
Connecting the inlet to the sump or aquarium:
- The rear left water tube port is used for KHA water intake and testing as well as for draining.
- A silicone tube with an inner/outer diameter of 3/5 mm is recommended. There is no length limit, but shorter lengths are preferred to reduce motor running time.
- Place the outlets of the calcium reactor or KH dosing in the area of the sump’s main pump.
- Attach the supplied flushing head to the end of the KHA inlet tube and place it in the overflow area to prevent highly concentrated seawater with high KH from being drawn in.
- Make sure the tube does not float above the water surface to avoid drawing in air. Do not place it near sludge at the bottom to prevent clogging.
Connecting the power supply:
- Connect the 12V output of the power supply.
- Plug the power supply into the socket. The KH controller switches on.
Do not connect the KH dosing tube immediately:
- Wait approx. three days until the KH measurement has stabilised and the KH calibration is complete.
- Connect the KH dosing tube after setting the [KH Dosing] parameters on the website.
- Do not drain directly into the aquarium at first. Instead, use a container to test the accuracy of the dosed amount.
- After successful verification, you can drain into the aquarium.
Switching on the AquaWiz:
- After switching on, the device automatically tests each pump. The motors rotate as follows: the first motor turns clockwise, then anticlockwise, followed by the third motor. The fourth motor only turns anticlockwise.
- The device enters the settings menu. If no button is pressed, the KH measurement starts automatically after 30 seconds.
- Press any button to call up the settings menu again. After 30 seconds the menu automatically switches to the KH measuring cycle. This can be interrupted by pressing any button.
- One measurement takes 20 minutes (including 15 minutes for bubbling). The automatic KH measurement at start-up is useful in the event of power failures.
- Due to the fresh surface conditions of the new KH controller, it may take up to three days for stable KH values to be reached.
Main menu:
- Input method:
- Three buttons, from left to right: [- / L], [+ / R], [Enter / Select]
WiFi connection (initial configuration required)
- Select [WiFi] in the LCD menu.
- Connect your smartphone or computer to the AquaWiz KH WiFi network.
- After a successful connection, the default browser will display the screen on the right.
- Enter the name of your home WiFi or mobile hotspot (SSID), the password and your time zone.
- Click [Connect] and the KH controller connects to the internet. After a successful connection, only the entered data is displayed.
What to do if the WiFi connection fails?
- If the connection fails, [AP Fail!] is displayed together with the previously entered values. Check upper/lower case and spaces, and avoid the '&' symbol. Reset accordingly. A weak WiFi signal, AP restrictions or external network congestion can cause connection errors. If necessary, use a mobile hotspot as the AP. If this works, there is a problem with the wired AP station or the network.
- AquaWiz can only connect to a 2.4 GHz network. The 2.4 GHz and 5 GHz frequencies on WiFi 6 routers must not share the same SSID (WiFi name). A successful connection shows the correct time during measurements. In the event of connection errors, [00:00] is displayed.
- If no connection is possible, the device can still carry out measurements and KH dosing based on previous settings, but cannot upload data or download setting changes from the website. For temporary changes, create a mobile hotspot, connect the KHA WiFi to this hotspot, make the changes and select [Sync] to download the settings. Once complete, the hotspot can be deactivated.
- If the connection is lost, hourly KH data cannot be uploaded and is lost. A later restoration of the connection does not upload the previously lost KH data.
Refilling reference seawater in the container:
- Open the menu and select [Other]. Press the select button to skip the [KH to PH output] setting.
- Then select [Fill], and the device automatically fills the water box up to the marked level.
- Once complete, the measuring process starts automatically and takes approx. 20 minutes.
If you want to change the water, select [Refill]. The device automatically drains and refills the water, which takes approx. 40 minutes. Once complete, the measuring process starts automatically.
Automated KH measuring process:
- After the water box has been filled, or from within the settings menu, the KH measuring process starts automatically after 30 seconds.
- KH: Aquarium KH value. The first KH value is measured approx. 20 minutes after the process starts.
- LF 100: pH probe lifetime at 100%. If this value is below 100, plan to replace the pH probe. It takes about a week for the value to drop to zero, indicating that the probe no longer works. After replacing the pH probe, wait approx. 3 minutes. If the display shows [Error], the pH probe is not plugged in or the pH probe circuit is interrupted.
- A6: Step 6 in the process.
- 19:35: Current time. When connected to the internet for time synchronisation, the correct time indicates a normal connection.
- L: Water level slightly low. H: Water level slightly high. The system automatically adjusts to the optimal water level after a few hours. If nothing is displayed, the level is optimal.
- Rep: If the difference from the previous measurement is greater than 0.2, a repeat measurement is triggered.
[Pump] Calibrating the water level in the test tubes (initial configuration required)
- While the measurement is progressing to the sixth step (shown as A6 on the LCD), you can press any button to open the main menu.
- Select [Pump] to adjust the water level in the chambers. The water level adjustment is not displayed in other steps. For an immediate adjustment, unplug the device and start at A2.
- Select [Pump] to adjust the water level in the test tubes. If the right test tube contains no water and motor A5 is rotating, check whether the intake tube to the aquarium is submerged. If the intake tube is not submerged and draws in air, this may be due to the length of the intake tube.
- Adjust the water level in the test tubes as follows: when [Tune Left Tube] is displayed, set the water level of the left test tube.
- Press the increase or decrease buttons to adjust the water level to the scale, then press the Enter button.
- Switch to the right test tube and repeat the same steps to complete the water level calibration of the right test tube.
- After prolonged use, if the water level difference is within 0.5 cm and the measurements are not affected, an adjustment may not be necessary.
-------------------------------
Manufacturer information:
Product name: AquaWiz
Postal address EU distribution: Fauna Marin GmbH, Gottlieb-Binder-Str.9, 71088 Holzgerlingen, Germany
Electronic contact address EU distribution: Fauna Marin GmbH: info@faunamarin.de
Electronic contact address manufacturer: aquawiz.kh@gmail.com, www.aquawiz.net
Technical Data AquaWiz Smart Display
Display type | Full-colour touchscreen |
Connectivity | Wireless connection to the AquaWiz KH Controller |
Dimensions | approx. 8.9 × 8.9 × 1.9 cm (3.5 × 3.5 × 0.75 in) |
Power connector | USB-C |
Power supply | Standard 5V USB-C power adapter or powered USB-C port |
User interface | Multilingual |
Scope of delivery
- AquaWiz Wireless Touchscreen Display
- USB-C charging cable
Note: A USB power adapter is not included.
Mandatory legal information (GPSR / ElektroG / VerpackG / RED)
Manufacturer: Coral Bay Technology Ltd, 390 Chundr Road, Dayuan Taoyuan, 337 Taiwan, E-mail: aquawiz.kh@gmail.com, Web: aquawiz.net
Importer: Fauna Marin GmbH, Gottlieb-Binder-Str. 9, D-71088 Holzgerlingen, Germany, E-mail: sales@faunamarin.de, Tel.: +49 (0) 7031 613680-0
Product identification: AquaWiz Wireless Touchscreen Display, compatible with Gen 3 / Gen 4 / Gen 5 KH controllers. Item number: 10508V
WEEE Reg. No.: DE20387490 (Fauna Marin GmbH)
Safety instructions: For use in dry indoor areas only. Do not immerse in water or expose to moisture. Operate only with a suitable 5V USB-C power adapter. Do not open the housing.
Disposal information: At the end of its service life, this device must not be disposed of with household waste, but must be taken to a separate collection point for waste electrical and electronic equipment (crossed-out wheelie bin symbol).